Product Details
NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 480 VAC coil, open Square D NEMA Motor Starter, Type S, nonreversing, Size 5, 270A, 200 HP at 460 VAC, up to 100 kA SCCR, 3 phase, 3 pole, Motor Logic, 480 VAC coil, open Type S NEMA motor starters are used for full voltage starting and stopping of AC squirrel cage motors. Type S motor starters have ratings up to 810 amperes. This 3 pole NEMA Size 5 non-reversing starter has a 270 ampere rating. This NEMA Size 5 motor starter has 3 phase ratings of 75 HP at 200 VAC, 100 HP at 230 VAC and 200 HP at 460 and 575 VAC. This non-reversing NEMA motor starter has a Motor Logic overload relay with a 90A to 270A range to sense over current conditions. This NEMA starter has a 100 kA maximum SCCR (Short Circuit Current Rating) per UL508A when protected by an appropriate circuit breaker or fuse. Type S motor starters are available with replaceable coils in a wide variety of voltages. This starter has a 440/480 VAC 50/60 Hz operating coil wired for separate control. This NEMA starter is an open device without an enclosure. This starter is 17.56 inches tall, 8.56 inches wide and 8.75 inches deep. A wide variety of accessories are available for Type S starters. Type S NEMA starters are UL listed and CSA certified. Motor starter;No control units
Manuals & Documentation
Features
- A normally open holding circuit contact for three wire control is provided as standard
- Sizes 00-2 Starters use a Class 9999 SX11 auxiliary contact as the holding circuit contact
- Sizes 3-7 starters use a Class 9999 SX6 auxiliary contact as the holding circuit contact
- Class 8536 Type S Sizes 00-6 starters are provided with a melting alloy thermal overload relay as standard
- Interchangeable thermal units are available in standard trip (Class 20) Sizes 00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3
- Single-phase starters use one thermal unit; 3-phase starters use three thermal units
- Class 8536 Size 7 starters are provided with solid state MOTOR LOGICTM which features
- Selectable trip Class10/20
- Ground fault detection and Communication capabilities for future enhancement Ambient insensitive and features phase loss, phase unbalance and over-current protection
- Solid state Motor Logic overload relays are available for Sizes 00 - 7 starters
- Bimetallic overload relays are also available for Sizes 00-1
- Class 8536 magnetic starters are available in a wide variety of the following enclosures
- NEMA Type 1 General Purpose Enclosure
- NEMA Type 3R Rainproof, Sleet Resistant for Outdoor Use
- NEMA Type 4 & 4X Watertight and Dust tight
Specifications
Identifiers
| Manufacturer Part Number |
8536SGO1V06H30S
|
|---|
| GTIN |
00785901636137
|
|---|
General Information
| Manufacturer |
Schneider Electric
|
|---|---|
| Brand |
Square Dâ„¢
|
| Country Of Origin |
MX
|
| Warranty |
18 months
|
|---|---|
| Standards Approvals |
REACH Compliant | UL Listed | NEMA | PROP65: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65 Warnings.ca.gov | CSA Certified
|
Dimensions
| Dimensions |
17.56 in H x 8.56 in W x 8.75 in D
|
|---|
Technical Information
| Amperage Rating |
270 A
|
|---|---|
| Auxiliary Contact Rating |
Without
|
| Coil Voltage |
440 V AC, 480 V AC
|
| Control Type |
Separate control circuit
|
| Enclosure Type |
Open
|
| Frequency Rating |
50/60 Hz
|
| Number Of Poles |
3
|
|---|---|
| Overload Relay |
Solid state Motor Logic class 10/20
|
| Phase |
Three Phase
|
| Series |
8536S
|
| Type |
NEMA Motor Starter
|
| Voltage Rating |
600 V AC
|