AFC Cable Systems
Atkore
7005-60-00 MC-Stat Plus Type MCI-A Metal Clad Cable With Grounding and Neutral Conductor, Reel Packaging, 600 V AC, (6) 12 AWG Solid Copper Conductor, 1000 ft L
- MFR #:
- 7005-60-00
- UPC:
- 077680270948
- Item #:
- 214571
AFC Cable Systems
Atkore
7005-60-00 MC-Stat Plus Type MCI-A Metal Clad Cable With Grounding and Neutral Conductor, Reel Packaging, 600 V AC, (6) 12 AWG Solid Copper Conductor, 1000 ft L
- MFR #:
- 7005-60-00
- UPC:
- 077680270948
- Item #:
- 214571
Product Details
AFC Cable Systems MC-Stat® Plus Metal Clad Cable, Type MCI-A, Reel Packaging, 600 V AC, 6 Conductors, Solid Copper Conductor, 12 AWG Conductor, 0.663 in OD, 1000 ft Length, THHN Insulation, Interlocked Galvanized Steel Strip Jacket, Light Green Jacket, 90 deg C
Manuals & Documentation
Features
- A neutral per phase type MCI-A cable designed for multi-wire branch circuit applications
- Decreases the time it takes to identify a faulty circuit because only the affected 1-phase breaker will trip thus, reducing the length of unnecessary outages
- (3) 12 AWG solid phase, (3) 12 AWG neutral, (1) 12 AWG solid insulated, (1) 10 AWG bare bonding conductor
- Technically equivalent and economically superior to traditional raceway and wire installations
- Neutral per phase decreases the time it takes to identify a faulty circuit because only the affected single-phase breaker will trip thus, allowing the rest of the electrical systems to continue to operate and reducing the length of unnecessary outages
- Wrap Free
- Protective polypropylene covering is extruded directly over the THHN insulation to eliminate the need for an overall assembly tape wrapping the twisted conductors reducing installation time and general waste on the jobsite
- ColorSpec ID/Color-Trak ID System
- Lime green galvanized steel armor with phase ID painted directly onto the armor for added identification without the added step of opening up the panel to determine circuit type
- Armor plus full-sized aluminum ground wire is the equipment grounding mean, second equipment grounding means is full sized insulated copper grounding conductor
Specifications
Identifiers
| Manufacturer Part Number |
7005-60-00
|
|---|---|
| GTIN |
00077680270948
|
| UPC |
077680270948
|
|---|
General Information
| Manufacturer |
Atkore
|
|---|---|
| Brand |
AFC Cable Systems
|
| Country Of Origin |
US
|
| Standards Approvals |
UL 1569 | UL 83 | UL 1479 | UL 1581 | UL 2556 | UL File No. E80042 | NEC® 210.4(B), 330, 300.22(C), 230.43, 250.118, 392, 396, 503, 530, 517, 518, 530, 645 | Federal Specifications A-A-59544 (Formerly J-C30B) | Meets OSHA and HUD Requirements | Cable Tray Rated, Install per NEC® | UL Classified 1, 2 and 3 Hour Through (Fire Stop) Penetration Product R-14141 | Environmental Air Handling Space Installation per NEC® 300.22
|
|---|---|
| Application |
For branch circuit wiring for a variety of power distribution systems from lighting, to devices and receptacles, branch circuit to computers and other electronic equipment where additive harmonics currents from non-linear switching loads may be present
|
Dimensions
| Length |
1000 ft
|
|---|
Technical Information
| Conductor Size |
12 AWG
|
|---|---|
| Conductor Type |
Solid Copper
|
| Insulation Material |
THHN
|
| Jacket Color |
Light Green
|
| Jacket Material |
Interlocked Galvanized Steel Strip
|
| Number Of Conductors |
6
|
| Outside Diameter |
0.663 in
|
|---|---|
| Packaging Type |
Reel
|
| Temperature Rating |
90 deg C
|
| Type |
Type MCI-A
|
| Voltage Rating |
600 V AC
|