XCSTE5312 Preventa Corrosion-Resistant Dusttight/Watertight Turret Head Safety Interlock Switch, 300 V AC, 6 A, 50/60 Hz, 10 VA Power Rating, 2 Poles
- MFR #:
- XCSTE5312
- UPC:
- 785901466642
- Item #:
- 150539
XCSTE5312 Preventa Corrosion-Resistant Dusttight/Watertight Turret Head Safety Interlock Switch, 300 V AC, 6 A, 50/60 Hz, 10 VA Power Rating, 2 Poles
- MFR #:
- XCSTE5312
- UPC:
- 785901466642
- Item #:
- 150539
Product Details
Telemecanique Preventa™ Square D™ Safety Interlock Switch, Corrosion-Resistant Dusttight/Watertight Turret Head, Series: XCSTE, 300 V AC, 6 A, 50/60 Hz Frequency, 10 VA Power, 1NC-1NO Contact Configuration, 2 Pole, Slow Break/Break Before Make Action, Key Actuator, M16 x 1.5 Cable Gland/Screw Clamp Connection, Double Insulated Insulation, NEMA 4/4X/12/IP67 Enclosure, 3.7 in H x 4.33 in W x 1.3 in D Size, 1000000 Cycles Operating Cycles, -25 to 60 deg C Operating, Plastic, Environmental Conditions: -40 to 158 deg F Storage Temperature
Manuals & Documentation
Features
- With interlocking, locking by solenoid
- With solenoid unlock, ISO M16 cable gland and plastic enclosure
Specifications
Identifiers
| Manufacturer Part Number |
XCSTE5312
|
|---|---|
| GTIN |
03389110825084
|
| UPC |
785901466642
|
|---|---|
| EAN |
3389110825084
|
General Information
| Manufacturer |
YAGEO Corporation
|
|---|---|
| Brand |
Telemecanique
|
| Country Of Origin |
MX
|
| Warranty |
18 Months
|
|---|---|
| Standards Approvals |
RoHS Compliant | Green Premium | REACH Compliant | UL File No. E164353 | UL CCN NKCR | CSA File No. LR4408794 | CSA Class 3211 03 | CE Certified | CCC Certified | CSA C22.2 No. 14 | EN 1088/ISO 14119 | EN/IEC 60204-1 | EN/IEC 60947-5-1 | EN/ISO 12100 | UL 508 | EN/IEC 60947-1 | EN/ ISO 13849-1 | EN/IEC 61508 | ECCN: EAR99 | PROP65: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov
|
| Application |
Packaging, Handling, Robotics, Machine Tools, Presses, Automotive Sector, Safety Detection and Indoor/Outdoor Applications
|
Dimensions
| Size |
3.7 in H x 4.33 in W x 1.3 in D
|
|---|
Technical Information
| Action |
Slow Break/Break Before Make
|
|---|---|
| Actuator Type |
Key
|
| Amperage Rating |
6 A
|
| Connection Type |
M16 x 1.5 Cable Gland/Screw Clamp
|
| Contact Configuration |
1NC-1NO
|
| Enclosure Type |
NEMA 4/4X/12/IP67
|
| Environmental Conditions |
-40 to 158 deg F Storage Temperature
|
| Frequency Rating |
50/60 Hz
|
| Insulation Type |
Double Insulated
|
| Material |
Plastic
|
|---|---|
| Number Of Poles |
2
|
| Operating Cycles |
1000000 Cycles
|
| Operating Temperature |
-25 to 60 deg C
|
| Power Rating |
10
|
| Series |
XCSTE
|
| Type |
Corrosion-Resistant Dusttight/Watertight Turret Head
|
| Voltage Rating |
300 V AC
|