Bussmann
Eaton
ECNR4.5 Current Limiting Time Delay Fuse, 4.5 A, 250 V AC/125 V DC, 200 kA Interrupt, RK5 Class, Cartridge Body
- MFR #:
- ECNR4.5
- UPC:
- 782634507215
- Item #:
- 797153
Bussmann
Eaton
ECNR4.5 Current Limiting Time Delay Fuse, 4.5 A, 250 V AC/125 V DC, 200 kA Interrupt, RK5 Class, Cartridge Body
- MFR #:
- ECNR4.5
- UPC:
- 782634507215
- Item #:
- 797153
Product Details
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Manuals & Documentation
Features
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Current limiting provides component short circuit protection
- Provides motor overload, ground fault and short circuit protection
- Helps protect motors against burnout from 1-phasing on 3 ph systems
- The time delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved over current protection
- These fuses will override normal equipment current surges to reduce unnecessary fuse openings
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of 10 s
- 10 s minimum at 500% of ampere rating response time
Specifications
Identifiers
| Manufacturer Part Number |
ECNR4.5
|
|---|---|
| GTIN |
00782634507215
|
| UPC |
782634507215
|
|---|
General Information
| Manufacturer |
Eaton
|
|---|---|
| Brand |
Bussmann
|
| Country Of Origin |
MX
|
| Standards Approvals |
CE Marked
|
|---|---|
| Application |
AC Power Distribution System Mains, Feeders and Branch Circuit, Protection of Motors and Motor Branch Circuit, Protection of Transformers and Other Inductive Loads, General Purpose, Lighting, Heating and Other Non-Inductive Loads, Safety and Security Systems
|
Technical Information
| Amperage Rating |
4.5 A
|
|---|---|
| Body Size |
0.56 in Dia x 2 in L
|
| Body Type |
Cartridge
|
| Class |
RK5
|
| Element |
Dual
|
| Indicating Non Indicating |
Non-Indicating
|
| Interrupt Rating |
200 kA
|
| Mounting Type |
Holder
|
|---|---|
| Response Time |
10 s
|
| Series |
ECNR
|
| Terminal Type |
Ferrule
|
| Type |
Current Limiting
|
| Voltage Rating |
250 V AC/125 V DC
|