2304-42-00 Type MC Parking Deck/Lot Cable With Grounding and Neutral Conductor, Coil Packaging, 600 V AC, (2) 12 AWG Solid Copper Conductor, 250 ft L

MFR #:
2304-42-00
UPC:
077680115201
Item #:
78024
Product Details

The Parking Deck/Lot Cable™ has often replaced Schedule 40 and/or Schedule 80 PVC conduits, EMT, and rigid conduit for its flexibility, durability, and labor savings. Parking Deck/Lot Cable™ has a 50-mils PVC jacket over a galvanized steel armor. This is 10 mils thicker than Schedule 40 PVC conduit. The cable offers the same mechanical protection and performance of traditional raceway methods, with the ease of installation of a cable assembly.

Manuals & Documentation

Features

  • Cable System
  • Technically equivalent and economically superior to traditional raceway and wire installations
  • Buries 24 in deep by Code
  • 10 mils thicker than Schedule 40 PVC conduit
  • Versatile
  • Listed for -40 deg C low temperature use, sunlight, and oil resistant

Specifications

Identifiers

Identifiers
Manufacturer Part Number
2304-42-00
GTIN
00077680115201
Identifiers
UPC
077680115201

General Information

General Information
Manufacturer
Atkore
Brand
AFC Cable Systems
Country Of Origin
US
General Information
Standards Approvals
UL 83 | UL 1479 | UL 1569 | UL 1581 | UL 2556 | UL File No. E80042 | NEC® 230.43, 300.5, 392, 396.10(A), 330, 501, 502, 503, 530, 504, 505, 511.7, 513.7(A), 514.7, 515.7(A), 516.7(A), 680.21(A) | Federal Specifications A-A-59544 (Formerly J-C30B) | Class I and II Division 2 and Class III, Division 1 and 2 (per NEC® Articles 501, 502, 503, 530) for Hazardous Locations | Cable Tray Rated, Install per NEC® | Wet Locations per NEC® 330.10(11)(C)
Application
For branch circuit and feeder wiring for lighting, control and signal circuits in wet, dirty or oily locations, buried directly in earth or concrete, surface mounted or trenched for use in parking deck or parking lot applications, golf courses, ski mountains, docks, marinas, pumping stations and stadium lighting, also used in continuous runs to outdoor or underground swimming pool motors, pumps and related equipment, fished, exposed or concealed cable trays and direct sunlight

Dimensions

Dimensions
Length
250 ft

Technical Information

Technical Information
Conductor Size
12 AWG
Conductor Type
Solid Copper
Insulation Material
THHN/THWN
Jacket Color
Gray
Jacket Material
Interlocked Galvanized Steel Strip/PVC
Number Of Conductors
2
Technical Information
Outside Diameter
0.614 in
Packaging Type
Coil
Temperature Rating
75/90 deg C
Type
Type MC
Voltage Rating
600 V AC