2304-42-00 Type MC Parking Deck/Lot Cable With Grounding and Neutral Conductor, Coil Packaging, 600 V AC, (2) 12 AWG Solid Copper Conductor, 250 ft L
- MFR #:
- 2304-42-00
- UPC:
- 077680115201
- Item #:
- 78024
2304-42-00 Type MC Parking Deck/Lot Cable With Grounding and Neutral Conductor, Coil Packaging, 600 V AC, (2) 12 AWG Solid Copper Conductor, 250 ft L
- MFR #:
- 2304-42-00
- UPC:
- 077680115201
- Item #:
- 78024
Product Details
The Parking Deck/Lot Cable™ has often replaced Schedule 40 and/or Schedule 80 PVC conduits, EMT, and rigid conduit for its flexibility, durability, and labor savings. Parking Deck/Lot Cable™ has a 50-mils PVC jacket over a galvanized steel armor. This is 10 mils thicker than Schedule 40 PVC conduit. The cable offers the same mechanical protection and performance of traditional raceway methods, with the ease of installation of a cable assembly.
Manuals & Documentation
Features
- Cable System
- Technically equivalent and economically superior to traditional raceway and wire installations
- Buries 24 in deep by Code
- 10 mils thicker than Schedule 40 PVC conduit
- Versatile
- Listed for -40 deg C low temperature use, sunlight, and oil resistant
Specifications
Identifiers
| Manufacturer Part Number |
2304-42-00
|
|---|---|
| GTIN |
00077680115201
|
| UPC |
077680115201
|
|---|
General Information
| Manufacturer |
Atkore
|
|---|---|
| Brand |
AFC Cable Systems
|
| Country Of Origin |
US
|
| Standards Approvals |
UL 83 | UL 1479 | UL 1569 | UL 1581 | UL 2556 | UL File No. E80042 | NEC® 230.43, 300.5, 392, 396.10(A), 330, 501, 502, 503, 530, 504, 505, 511.7, 513.7(A), 514.7, 515.7(A), 516.7(A), 680.21(A) | Federal Specifications A-A-59544 (Formerly J-C30B) | Class I and II Division 2 and Class III, Division 1 and 2 (per NEC® Articles 501, 502, 503, 530) for Hazardous Locations | Cable Tray Rated, Install per NEC® | Wet Locations per NEC® 330.10(11)(C)
|
|---|---|
| Application |
For branch circuit and feeder wiring for lighting, control and signal circuits in wet, dirty or oily locations, buried directly in earth or concrete, surface mounted or trenched for use in parking deck or parking lot applications, golf courses, ski mountains, docks, marinas, pumping stations and stadium lighting, also used in continuous runs to outdoor or underground swimming pool motors, pumps and related equipment, fished, exposed or concealed cable trays and direct sunlight
|
Dimensions
| Length |
250 ft
|
|---|
Technical Information
| Conductor Size |
12 AWG
|
|---|---|
| Conductor Type |
Solid Copper
|
| Insulation Material |
THHN/THWN
|
| Jacket Color |
Gray
|
| Jacket Material |
Interlocked Galvanized Steel Strip/PVC
|
| Number Of Conductors |
2
|
| Outside Diameter |
0.614 in
|
|---|---|
| Packaging Type |
Coil
|
| Temperature Rating |
75/90 deg C
|
| Type |
Type MC
|
| Voltage Rating |
600 V AC
|