Square D™ Schneider Electric

EZM11600GCBUMS EZ Meter-Pak Rainproof Meter Center Main Unit With Energy Reduction Maintenance, 1600 A, Underground Feed, 1200 A Bus

MFR #:
EZM11600GCBUMS
UPC:
785901548300
Item #:
516176
Product Details

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main circuit breaker provides 1 phase in, 1 phase out for a 3 wire configuration. It accepts 120/240VAC incoming service from UG feeds. The unit is rated for 1600A with the busbar rated for 1200A. With ERMS (energy reducing maintenance switch), it has a short circuit current rating of 65kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.

Manuals & Documentation

Features

  • Main circuit breaker, fusible switch, or lug terminal boxes available
  • Meter-Pak units from 225A to 2000A
  • Visi-Tite nuts eliminate special tools and torque readings
  • Rotating mounting brackets pivot for drilling holes without moving the device
  • External mounting channels allow immediate installation
  • Compact footprint for installation flexibility

Specifications

Identifiers

Identifiers
Manufacturer Part Number
EZM11600GCBUMS
GTIN
00785901548300
Identifiers
UPC
785901548300
EAN
0785901548300

General Information

General Information
Manufacturer
Schneider Electric
Brand
Square D™
Country Of Origin
MX
Warranty
18 months
General Information
Standards Approvals
UL Listed | PROP65: This product can expose you to chemicals including: Lead and lead compounds which is known to the State of California to cause Carcinogen and Reproductive harm. For more information go to www.p65warnings.ca.gov
Application
For indoor application
Includes
Circuit Breaker, (1) 2P 1600 A 65 kA Main Supply and Ready Assembled and Closing Plate

Dimensions

Dimensions
Dimensions
30.2 in W x 18.31 in D x 68.9 in H

Technical Information

Technical Information
Bus Amps
1200 A
Enclosure Type
NEMA 3R
Feed Type
Underground
Mounting Type
Wall
Technical Information
Phase
1
Socket Amps
1600 A
Type
Rainproof