Pressure switches, float switches, vacuum switches and power pressure switches for control or monitoring of water pumps, compressors, agricultural/irrigation water systems, moulding presses, injection moulders, grinding machines, machining centers, complex and special machines, HVAC, automotive, food and beverage, healthcare facilities, pharmaceutical and more. Classes 9013.
Manuals & Documentation
Features
- 9013F power pressure switches rated for the direct control of motors in pump and compressor applications
- Rugged, robust construction provides a long life and provides years of uninterrupted, worry-free service
- Drift proof cut-in and cut-out settings
- Has visible vertical contacts, easy to inspect without removal
- An extra strong frame that resists distortion when mounting the switch to a compressor
- Designed for the direct control of motors in pump and compressor applications
- 1/4 in NPSF Internal pressure
- 30 to 50 psi pressure
- Adjustable differential <= 2 hp, standard action
- Low pressure cut-off (auto-start-off) FSG, FYG
Specifications
| Manufacturer Part Number | 9013FYG2J21M4 |
| Brand | Square Dâ„¢ |
| Manufacturer | Schneider Electric |
| UPC | 785901399070 |
| EAN | 0785901399070 |
| Country Of Origin | MX |
| Enclosure Type | IP20/NEMA 1 |
| Housing Material | Polypropylene |
| Series | 9013 |
| Temperature Rating | -33 to 257 deg F |
| Type | Type F |
| Alternative Part Number | 8026908 |
| Manufacturer Item Status | Active |
| Country | USA |
| Warranty | 18 Months |
| Standards Approvals | ECCN: EAR99 | CSA Certified | IEC 60529 | REACH Compliant | UL 508 | PROP65:This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov |
| Application | Industrial, Pressure control or monitoring of water pumps, compressors, agricultural/irrigation water systems, moulding presses, injection moulders, grinding machines, machining centers, complex and special machines, HVAC, automotive, food and beverage, healthcare facilities, pharmaceutical and Control electrically driven water pumps |
| Connection Material | Zinc Plated Steel |
| Connection Type | Screw Clamp |
| Contact Configuration | 2NC DPST-DB |
| Diaphragm Material | Nitrile |
| Operating Cycles | 10 cpm |
| Pressure Rating | 5 to 60 psig |