FLK-3000FC-IND FC Series Wireless Digital Multimeter, 1000 V AC/DC, 400 mA, 50 MOhm Measuring, 600 mV, 6/60/600/1000 VAC/VDC, 400 mA, 50 MOhm, LCD Display
- MFR #:
- FLK-3000FC-IND
- UPC:
- 095969724180
- Item #:
- 342216
FLK-3000FC-IND FC Series Wireless Digital Multimeter, 1000 V AC/DC, 400 mA, 50 MOhm Measuring, 600 mV, 6/60/600/1000 VAC/VDC, 400 mA, 50 MOhm, LCD Display
- MFR #:
- FLK-3000FC-IND
- UPC:
- 095969724180
- Item #:
- 342216
Product Details
New Fluke® connect mobile application, wireless technology allows connectivity between your phone, PC and all Fluke® connect enabled test tools, let your team see what you see in an instant with ShareLive™ video call, save money and time by taking multiple measurements simultaneously, isolate intermittent events or record signal fluctuations without even being there using the log function on the modules. View results on your computer with the PC adapter. Work with fewer interruptions by recording multiple sessions before downloading. Data is saved to a PC in .csv format (comma separated variable) file format for easy viewing at your convenience. Capture readings at different intervals, with user set recording intervals from 1s to 1hr. Future proof your investment by adding functionality to the 3000 FC DMM when you need it. Send and communicate test data to your manager and coworkers to assess abnormal system response in seconds. Have all asset test results at your fingertips after downloading to your PC for future asset performance tracking and reliability programs. See multiple measurements on one screen at one time (DMM and three modules, Ti200 300/400 and five modules). No more writing data down. Capture up to 65000 sets of min/max/AVG readings over single or multiple logging sessions using the recording capability. Each reading and session is time stamped. Avoid awkward or uncomfortable measurement positions. Setup the measurement once, step back and read it as many times as you want, when you want. View up to 6 live readings at once on the Fluke® connect mobile application or a PC to get a complete understanding of the situation. Easily see backlit displays in dark or dimly lit work environments. Choose auto or manual ranging. Use the optional TPAK magnetic hanger for even more hands-free working. Integrated holster protects the meters, while probe holders keep accessories organized. Be in multiple places at once, reducing the risk of arc flash by separating yourself-from hazardous measurement situations.
Manuals & Documentation
Features
- Communicate with your iOS (4S and later) and Android™ (4.3 and up) devices with the new Fluke® connect mobile application
- Resistance range - 600 Ohm with accuracy of +/-(0.5% 2), 6 kOhm, 60 kOhm, 600 kOhm with accuracy of +/-(0.5% 1), 50 MOhm with accuracy of 1.5% 3
- Capacitance range 1000 nF, 10 uF, 100 uF with accuracy of (1.2% 2), 9999 uF with accuracy of 10% typical
- Frequency range 99.99 Hz, 999.9 Hz, 9.999 kHz, 99.99 kHz with accuracy of (0.1% 1)
- 250 hr minimum battery life
- Be in multiple places at once, reducing the risk of arc flash by separating yourself from hazardous measurement situations
- Fluke® 3000 FC meets measurement category 1000 V CAT III and CAT IV 600 V safety standards, AC current clamp module and AC/DC current clamp module 600 V CAT III, AC voltage module, DC voltage module and iFlex® clamp meters 600 V CAT IV/1000 CAT III
- Wireless technology allows connectivity between your phone, PC and all Fluke® connect enabled test tools
- Let your team see what you see in an instant with ShareLive™ video call
- Save money and time by taking multiple measurements simultaneously
- Isolate intermittent events or record signal fluctuations without even being there using the log function on the modules
- View results on your computer with the PC adapter
- Work with fewer interruptions by recording multiple sessions before downloading
- Data is saved to a PC in csv format (comma separated variable) file format for easy viewing at your convenience
- Capture readings at different intervals, with user set recording intervals from one second to one hour
- Future proof your investment by adding functionality to the 3000 FC DMM when you need it
- Send and communicate test data to your manager and coworkers to assess abnormal system response in seconds
- Have all asset test results at your fingertips after downloading to your PC for future asset performance tracking and reliability programs
- See multiple measurements on one screen at one time (DMM and three modules, Ti200 300/400 and five modules)
- No more writing data down, capture up to 65000 sets of min/max/avg readings over single or multiple logging sessions using the recording capability
Specifications
Identifiers
| Manufacturer Part Number |
FLK-3000FC-IND
|
|---|---|
| GTIN |
00095969724180
|
| UPC |
095969724180
|
|---|
General Information
| Manufacturer |
Fluke
|
|---|---|
| Brand |
Fluke®
|
| Country Of Origin |
US
|
| Standards Approvals |
ANSI/ISA 61010-1/(82.02.01) | CAN/CSA C22.2 No 61010-1-12 | UL 61010-1 | IEC/EN 61010-1:2010 | IP54 Pollution Degree 2 | EN 61326-1:2006 | EN 61326-2-2:2006 | ETSI EN 300 328 V1.7.1:2006 | ETSI EN 300 489 V1.8.1:2008 | FCC Part 15 SubPart C Section 15.207 | FCC Part 15 SubPart C Section 15.209 | FCC Part 15 SubPart C Section 15.249 | FCCID:FCC:T68-FDMMBLE IC: 6627A-FDMMBLE | FCC Approved | CE Marked | ECCN: 3A992 | PROP65: This product is in compliance with Prop65, it is not known to contain any chemicals associated with this regulation
|
|---|---|
| Application |
For troubleshooting and repair of electrical and electronic systems
|
Dimensions
| Dimensions |
8.14 in L x 3.68 in W x 1.87 in H
|
|---|
Technical Information
| Accuracy |
1% + 3 (45 to 500 Hz), 2%+3 (500 Hz to 1 kHz) for V AC, (9%+2), (0.15%+2) for V DC
|
|---|---|
| Amperage Rating |
400 mA
|
| Battery Type |
(3) AA Alkaline, NEDA 15 A/IEC LR6 A
|
| Capacitance |
9999 uF
|
| Diode Test |
Yes
|
| Display Type |
LCD
|
| Frequency Rating |
99.99 kHz
|
| Material |
Hard Plastic
|
| Measuring Range |
1000 V AC/DC, 400 mA, 50 MOhm
|
|---|---|
| Peak Hold |
Yes
|
| Resistance |
50 MOhm
|
| Safety Rating |
CAT III 1000 V AC/DC, CAT IV 600 V AC/DC Pollution deg 2
|
| Series |
FC Series
|
| Temperature Rating |
-10 to 50 deg C
|
| Type |
Wireless
|
| Voltage Rating |
600 mV, 6/60/600/1000 V AC/DC
|