Tapered threaded male hub NPT
Compact, slim diameter with small turning radius
UL listed
Detailed Description: Appleton liquid tight connector has tapered threaded male hub NPT, compact, slim diameter with small turning radius. It secures, grounds and seals liquid tight flexible metal conduit and terminates bonding conductor run externally alongside liquid tight conduit.
Application | For Liquidtight Flexible Metal Conduit |
Brand | O-Z/Gedney |
Catalog Description | OZ-Gedney Type 4Q-T Liquid Tight 45 DEG Connector, Size: 1/2 IN, Connection: Compression X Tapered MNPT Hub, Malleable Iron Body And Nut, Steel Ferrule, Finish: Zinc Electroplated, NEMA Rating: NEMA 4, Insulated Throat, 1-1/4 IN Width, Dimension A |
Connection | Compression X Tapered MNPT Hub |
GTIN | 00783126618303 |
Height | 0.3900 |
Height Unit | IN |
Insulation | Insulated Throat |
Item Status | A |
Length | 4.8000 |
Length UOM | IN |
Material | Malleable Iron Body And Nut, Steel Ferrule |
Mfr. # | 4Q-450T |
Nema Rating | 4 |
Special Features | "4Q-T fittings have insulated throat to protect against wire damage;Bonding wedge locknuts are recommended in hazardous locations;Compact, slim diameter with small turning radius;Furnished with locknut and Knockout sealing ring;Hot dip or mechanically galvanized finish optionally available;Inspection windows in fe;Intrinsically safe;Liquidtight/raintight/oiltight/concretetight;Long ferrule prevents pullout and tight bend conduit ""pop-out"";O-Z/Gedney fittings are used with liquidtight flexible metal conduit to provide a dependable connection and are suitable for use in wet locations;Reusable ferrule;Suitable for grounding through 1-1/4 IN trade size (for larger trade sizes, an internal or external equipment bonding conductor is required);UL listed NEMA type 4 when installed into a NPT threaded entry or UL listed conduit hub (sizes 1-1/4 IN and larger require thread sealant);Used to secure, ground and seal liquidtight flexible metal conduit, Type LFMC, to boxes and enclosures" |
Standard | Third Party Certification: UL File Number 11853, CSA 009795, Applicable Third Party Standards: UL 514B, CSA C22.2 No.18, Federal Specification W-F-406E, NEMA : FB-1, Hazardous Locations: Class I, Division 2 Per NEC 501.4(B), Class I, Zone 2 Per NEC 505.15(C)(2), Class II, Division 1 Per NEC 502.4(A)(1)(e), Class II, Division 2 Per NEC 502.4(B)(2), Class III, Division 1 Per NEC 503.3(A)(2), Class III, Division 2 Per NEC 503.3(B), Intrinsically Safe Per NEC 504.20 |
Type | Type 4Q-T Liquid Tight 45 DEG Connector |
UNSPSC | 39121420 |
Width | 4.3000 |
Width UOM | IN |