Size: 11.250 Inch Width x 3.250 Inch Depth x 11.125 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
Detailed Description: GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kAIC. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting rating of 65 Kilo-Amps. It measures 11.250 Inch x 3.250 Inch x 11.125 Inch. It has top/bottom feed for convenience. Load center has 16 circuits, eight spacing of 1-Inch and 42/4/24/16 spacing of 1/2-Inch for convenient operation. Load center has conductor temperature rating of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. It has plug in breaker mounting for easy installation. Load center is UL listed, CSA certified and GSA complaint.
Amperage Rating | 125 A |
Brand | GE |
Catalog Description | Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 2FCU8034 |
Enclosure | Indoor |
GTIN | 00783164268034 |
Height | 4.2500 |
Height Unit | IN |
Interrupt Rating | 65 |
Item Status | A |
Length | 13.0000 |
Length UOM | IN |
Load Regulation | 120/240V ac |
Mfr. # | TLM812FCU |
Mounting | 0 |
Number Of Feeders | Either |
Phase | 1 Phase |
Special Features | "PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM812FCU features space for 8, 1"" breakers, 125 A bus ampere rating, a copper bus, an optional door for 6-8 circuit panel, a factory installed ground bar, and a surface enclosure." |
Standard | UL |
Type | Standard |
UNSPSC | 39121101 |
Width | 13.0000 |
Width UOM | IN |
Wiring Configuration | 3 Wire |