Size: 15.360 Inch Width x 3.750 Inch Depth x 40.560 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
Detailed Description:
GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible main load center has durable copper bus construction. It has voltage rating of 120/240 VAC and current rating of 200 Amps. It has interrupting rating of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has THQL type main breaker for added safety and protection. Load center has 40 circuits, 40 spacing of 1-Inch and 40/42/4/24/16/20/32 spacing of 1/2-Inch for convenient operation. Load center has 40 spaces for 1-Pole/1-Inch THQL breakers and 20 spaces for 2-Pole/1-Inch THQL breakers.
Load center operates at a temperature of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. It has flush/surface cover to improve aesthetic look. It can accommodate 6 AWG-250 kcmil aluminum/copper wires. It has plug in breaker mounting for easy installation. It measures 15.360 Inch x 3.750 Inch x 40.560 Inch. Load center is UL listed, CSA certified and GSA complaint.
Amperage Rating | 200 |
Brand | GE |
Catalog Description | Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 200 A 0CCU2405 |
Enclosure | Indoor |
GTIN | 00783164112405 |
Height | 39.2 |
Height Unit | IN |
Interrupt Rating | 65 |
Item Status | A |
Length | 41.2500 |
Length UOM | IN |
Load Regulation | 120/240V ac |
Mfr. # | TLM4020CCU |
Mounting | 0 |
Number Of Feeders | Either |
Phase | 1 |
Special Features | "PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM4020CCU features space for 40, 1"" breakers, a 200 A bus ampere rating, a copper bus, and a combintation/flush enclosure." |
Standard | UL |
Type | Standard |
UNSPSC | 39121101 |
Width | 16.0000 |
Width UOM | IN |
Wiring Configuration | 3 Wire |