Size: 15.360 Inch Width x 3.310 Inch Depth x 17.380 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
Detailed Description:
GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard load center has durable copper bus construction. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting rating of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has THQL/THQP type main breaker for added safety and protection. Load center has 24 circuits, 12 spacing of 1-Inch and 42/4/24/16/20/32/40 spacing of 1/2-Inch for convenient operation. It measures 15.360 Inch x 3.310 Inch x 17.380 Inch. Load center has 12 spaces for 1-Pole/1-Inch THQL breakers and 6 spaces for 2-Pole/1-Inch THQL breakers. It has 24 spaces for 1-Pole/0.5-Inch THQP breakers and 10 spaces for 2-Pole/0.5-Inch THQP breakers. It has centered key holes, slotted mounting holes and ground bar for easy installation.
Load center has optimum wire-bending space, more breaker capacity and improved safety makes it best among all other load centers. Load center operates at a temperature of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. Load center is UL listed, CSA certified and GSA complaint.
Amperage Rating | 125 |
Brand | GE |
Catalog Description | Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, except where noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down No lock provision available. Use compatible load center with the suffix C24 with a TDL106 for locking provision For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 2CCU2313 |
Enclosure | Indoor |
GTIN | 00783164112313 |
Height | 19 |
Height Unit | IN |
Interrupt Rating | 65 |
Item Status | A |
Length | 17.7500 |
Length UOM | IN |
Load Regulation | 120/240V ac |
Mfr. # | TLM1212CCU |
Mounting | 0 |
Number Of Feeders | Either |
Phase | 1 |
Special Features | "PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM1212CCU features space for 12, 1"" breakers, a 125 A bus ampere rating, a copper bus, and a combination/flush enclosure." |
Standard | UL |
Type | Standard |
UNSPSC | 39121101 |
Width | 16.0000 |
Width UOM | IN |
Wiring Configuration | 3 Wire |