Explosion proof, dust-ignition proof and raintight
Smooth, rounded integral bushing in each hub
Accurately tapped, tapered threads for tight
Allow up to 40% conduit fill in compliance with the National Electrical Code (NEC)
Detailed Description: Appleton sealing fitting prevent passage of gases, vapours or flames from one portion of conduit system to another. Restrict any explosion to the sealed off enclosure. Prevent pressure piling within conduit system.
Application | For Use With Threaded Rigid Metal Conduit and IMC |
Brand | Appleton |
Catalog Description | UNILETS EY Series 40 PCT Expanded Fill Vertical And Horizontal Conduit Sealing Fitting, Size: 2 IN, Material: Malleable Iron, Finish: Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat), Connection: Female Threaded, Turning Radius: 2.63 IN, Length: 7-1/2 IN, Width: 3-1/2 IN, Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D, Class II, Groups E, F, G, And Class III, For Use With Threaded Rigid Metal Conduit and IMC |
Connection | Female Threaded |
Finish | Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat) |
GTIN | 00781381694339 |
Height | 4.6000 |
Height Unit | IN |
Item Status | A |
Length | 9.3000 |
Length UOM | IN |
Material | Malleable Iron |
Mfr. # | EYSEF200 |
Size | 2 |
Special Features | For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; A |
Standard | UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D; Class II, Groups E, F, G; And Class III |
Type | EY Series 40 PCT Expanded Fill Vertical And Horizontal Conduit Sealing Fitting |
UNSPSC | 39121311 |
Width | 5.8000 |
Width UOM | IN |