Sign in or register to view your pricing and inventory.

ACME T181048 Electric Buck-Boost Transformer; 100 VA, 1-Phase, Non-Encapsulated, Indoor/Outdoor, 50/60Hz

  • Acme Transformer T181048 ACME T181048 Electric Buck-Boost Transformer; 100 VA, 1-Phase, Non-Encapsulated, Indoor/Outdoor, 50/60Hz
Manufacturer: Acme Transformer
Mfr. #: T181048
Item #: 129533
UPC: 047503183366
Login for Availability
Your Price:

Product Details

Detailed Description: T181048 ACME .100KVA BUCK&BOOST

Product Specification

Application For Low Voltage Lighting Or Control Circuitry
Boost Voltage 1.01 KVA/4.17 AMP: 220 V Line And 242 V Load
Brand Acme Electric
Catalog Description Acme Electric T-1-81048 Transformer, Encapsulated Core And Coil Buck-Boost, 120/240 V, 12/24 V, 2.04 KVA/8.75 AMP: 252 V Line And 240 V Load Buck Voltage, 1.01 KVA/4.17 AMP: 220 V Line And 242 V Load Boost Voltage, 60 HZ, 1 PH, 8.32 AMP At 12 V, 4.16 AMP At 24 V, 115 DEG C Rise, Wire Lead Screw Terminal Connection, 130 DEG C Class B Insulation, Wall Mounting, NEMA 3R, 3.89 IN Length, 3.67 IN Width, 7.16 IN Height, 0.10 KVA, Steel, Configuration: Primary: Two Winding, Secondary: Two Winding, UL 506, UL File Number E79947V1, UL Control Number 50B8, UL Insulation Number B3223, CSA Certified, OSHA Compliant, ANSI, IEEE, For Low Voltage Lighting Or Control Circuitry
Connection Wire Lead Screw Terminal
Enclosure NEMA 3R Steel
Frequency Rating 50/60
GTIN 00047503183366
Height 7.16
Height Unit IN
Insulation Class 130 DEG C Class B
Item Status A
Length 3.67
Length UOM IN
Maximum Output Current 8.32 AMP At 12 V, 4.16 AMP At 24 V
Mfr. # T181048
Mounting Wall
Number Of Phases 1
Primary Voltage 120 X 240 V
Replaced UPC 047503183366
Secondary Voltage 12/24 V
Special Features Encapsulated core and coil; Buck-boost transformers are small single phase transformers designed to reduce (buck) or raise (boost) line voltage from 5 - 20 PCT; The most common example is boosting 208 - 230 V, usually to operate a 230 V motor such as an air-conditioner compressor, from a 208 V supply line; Buck-boost transformers are an economical way to correct a potentially very serious problem; Anytime a line voltage change in the 5 - 20 PCT range is required, a buck-boost transformer should be considered as your first line of defense; 10-year limited warranty
Standard UL 506, UL File Number E79947V1, UL Control Number 50B8, UL Insulation Number B3223, CSA Certified, OSHA Compliant, ANSI, IEEE
Temperature Rating 115 DEG C Rise
Type Buck-Boost Transformer
UNSPSC 39121025
Width 3.89
Width UOM IN