The time delay of the 3 output circuits is adjustable between 0 and 30 seconds
Module PASTE incorporates 4 solid-state signaling outputs for signaling to the process PLC
To aid diagnostics, the modules have LEDs which provide information on the monitoring circuit status
The Start button monitoring function is configurable depending on the wiring
Detailed Description: Square D by Schneider Electric safety modules PASTE are used for monitoring Emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and also meet the safety requirements for the electrical monitoring of switches in protection devices conforming to standard EN/ISO 14119.
Brand | SCHNEIDER ELECTRIC |
Catalog Description | Schneider Electric,Safety Relay with Timing Function, 120 V,35 mm symmetrical DIN rail,48 V DC,Preventa Safety automation,emergency stop button with 2 NC contacts,for emergency stop and switch monitoring,Preventa safety module |
GTIN | 00785901853800 |
Height | 2.4000 |
Height Unit | IN |
Item Status | A |
Length | 4.8000 |
Length UOM | IN |
Mfr. # | XPSATE3410P |
UNSPSC | 32151802 |
Width | 4.3000 |
Width UOM | IN |