Sign in or register to view your pricing and inventory.

Square D GV7RE50 Manual Motor Starter, 600 VAC, 30 - 50 A, 3-Pole

  • Square D - Schneider Electric GV7RE50 Square D GV7RE50 Manual Motor Starter, 600 VAC, 30 - 50 A, 3-Pole
Manufacturer: Square D - Schneider Electric
Mfr. #: GV7RE50
Item #: 468483
UPC: 785901602583
Login for Availability
Your Price:

Product Details

CSA Certified

UL Listed

Product Details:

Detailed Description: GV7RE50 SQD MANUAL STARTER 600VAC 50AMP IEC

Warranty: https://s3.amazonaws.com/cesco-content/unilog/Batch7/785901/100036-WarrantyURL.pdf

Product Specification

Brand Schneider Electric
Catalog Description GV7RE50 is a TeSys GV7R motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors [email protected] with breaking capacity Icu 36kA. Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. GV7RE50 is a TeSys GV7R motor circuit breaker from Schneider Electric designed for motor applications [email protected] It fulfills thermal-magnetic protection with a thermal setting range 30-50A, magnetic tripping at 12-14xIn and breaking capacity Icu [email protected] Start-stop control by rocker lever guaranteed for 30 000 cycles AC-3 415V. Available worldwide, it is multi-standards certified (IEC, UL, CSA, Marine).. Complete motor protection in a single device : short-circuit, overload, disconnection. Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution . For industrial or building LV distribution networks thanks to 36kA breaking capacity. Power connections with screw clamp terminals. Manual control with rocker lever for Start / Stop, padlockable with accessory (GV7V). Possible integration of auxiliary contacts (GV7AB, GV7AD, GV7AE) for status and tripping signalling. Possible integration of undervoltage or shunt tripping units (GV7AU, GV7AS).
Connection SCREW CLAMP
Enclosure IP405 WITH TERMINAL SHROUDS CONFORMING TO IEC 60529
GTIN 00785901602583
Height 6.9000
Height Unit IN
Item Status A
Length 4.4000
Length UOM IN
Mfr. # GV7RE50
Motor Power NOT RATED [email protected] - [email protected] - [email protected]
Mounting BY CLIPS-BY SCREWS
Operating Cycles 50000 CYCLES
Operating Temperature -25...70 ¦C
Reset Type AMBIENT COMPENSATED BIMETALLIC (CLASS 10) 30A TO 50A
Special Features IP405 WITH TERMINAL SHROUDS CONFORMING TO IEC 60529
Standard UL LISTED FILE NUMBER: E164864 NLRV - CSA CERTIFIED FILE NUMBER: LR81630 CLASS: 3211 05 - CE MARKED
Sub-Brand TESYS,TESYS GV7
Type GV7RE,CIRCUIT BREAKER
UNSPSC 39121521
Voltage Rating 690 V AC 50/60 HZ CONFORMING TO IEC 60947-2,750 V AC 50/60 HZ CONFORMING TO IEC 60947-2
Width 5.6000
Width UOM IN