Sign in or register to view your pricing and inventory.

Schneider Electric / Square D 60969 Multi 9™ Ground Fault Protector; 25 Amp, 480Y/277 Volt At 60 Hz (UL1053), 230/400, 240/415 Volt At 50 Hz (IEC 61008), 2-Pole, DIN Rail Mount

  • Square D - Schneider Electric 60969 Schneider Electric / Square D 60969 Multi 9™ Ground Fault Protector; 25 Amp, 480Y/277 Volt At 60 Hz (UL1053), 230/400, 240/415 Volt At 50 Hz (IEC 61008), 2-Pole, DIN Rail Mount
  • Schneider Electric / Square D 60969 Multi 9™ Ground Fault Protector; 25 Amp, 480Y/277 Volt At 60 Hz (UL1053), 230/400, 240/415 Volt At 50 Hz (IEC 61008), 2-Pole, DIN Rail Mount
Manufacturer: Square D - Schneider Electric
Mfr. #: 60969
Item #: 76846
UPC: 785901800323
Login for Availability
Your Price:

Product Details

Dimension: 1.420 Inch Width x 3 Inch Depth x 3.190 Inch Height

Provides no thermal or magnetic protection, the circuit must be protected by an upstream device

Contains Si technology to increase immunity to noise and to minimize the potential for nuisance tripping in noisy electrical environments

Detailed Description: Schneider Electric/Square D Multi 9™ Ground fault protector has a voltage rating of 480Y/277 VAC at 60 Hz, 230/400, 240/415 Volts at 50 Hz and current rating of 25 Amps. Fault protector has standard DIN-rail mounting to hold the breaker in place. The 2-Pole protector is ideally designed to offer superior protection from the effects of ground faults. Ground fault protector has maximum sensitivity of 30 milli-Amps and tripping range of 22.1 - 29.9 milli-Amps. It measures 1.420 Inch x 3 Inch x 3.190 Inch.

Product Specification

Actuator TOGGLE
Amperage Rating 25 A 40 AC
Application GFP
Brand SCHNEIDER ELECTRIC
Catalog Description Schneider Electric,GFP 2P 25A 30mA AC SiE 480Y/277V,230/400 V AC 50 Hz-240/415 V AC 50 Hz-240 V AC 60 Hz-480Y/277 V AC 60 Hz,230/400 V AC 50 Hz-240/415 V AC 50 Hz-240 V AC 60 Hz-480Y/277 V AC 60 Hz,50/60 Hz,GFP,GFP,earth leakage protection,ground fault protector
Connection TUNNEL TYPE TERMINALS 2.5-35 MMA FLEXIBLE-TUNNEL TYPE TERMINALS 2.5-35 MMA RIGID
Frequency Rating 50/60
GTIN 00785901800323
Height 81 MM
Height Unit IN
Interrupt Rating 240 V AC 60 HZ-480Y/277 V AC 60 HZ-230/400 V AC 50 HZ-240/415 V AC 50 HZ
Item Status A
Length 75 MM
Length UOM IN
Mfr. # 60969
Number Of Poles 2
Operating Temperature -25-60 AC
Ships Freight No
Ships Ground. Eligible for expedited shipping Yes
Special Features FAULT INDICATION,PADLOCKING IN OFF POSITION
Standard IEC 61008-UL 1053,IP20IEC 60529-IP40IEC 60529-IPXX BIEC 60529
Sub-Brand GFP,MULTI 9 GFP
Type RESIDUAL CURRENT CIRCUIT BREAKER (RCCB)
UNSPSC 39121603
Voltage Rating 240 V AC 60 HZ-480Y/277 V AC 60 HZ-230/400 V AC 50 HZ-240/415 V AC 50 HZ
Width 36 MM
Width UOM IN