Size: 14-3/4 Inch Width x 6-7/16 Inch Depth x 21-3/8 Inch Height
With circuit breaker protection
LC1212PC load center
8 extra spaces for circuit breakers
14 x 21 Inch cutout Size
Hub, (9) Knockouts Cable Entry
Detailed Description: Midwest 1-Phase Unmetered surface service entrance equipment features G90 galvanized steel construction and electro deposited finish to offer resistance against corrosion and fading. Equipment has voltage rating of 120/240 Volts, current rating of 200 Amps and short circuit current rating of 10 kilo-Amps. Unmetered equipment measures 14-3/4 Inch x 6-7/16 Inch x 21-3/8 Inch. It accommodates 2 AWG - 250 kcmil size of load. Equipment is suitable for outdoor applications.
Amperage Rating | 200 |
Brand | Midwest |
Cable Entry | Knockout Code (A): 1-1/2, 2, 2-1/2 IN; Knockout Code (C): 1-1/4, 1-1/2, 2 IN; Knockout Code (E): 3/4 IN; Knockout Code (Q): 1 IN |
Catalog Description | National Electric Code requires electrical distribution equipment to be rated as ôService Entranceö, wherever electrical power enters a building or other structure. Service entrance products are typically utilized on single-family residences and mobile homes. Midwest Electric offers a broad range of surface mount and pedestal units, factory assembled and wired. Pedestal units come standard with loop feed lugs to reduce installation time and labor expense. Service Entrance equipment is made of heavy, galvanized G-90 steel, preventing corrosion and fading. |
Cutout Size | 14 X 21 |
GTIN | 00784567562989 |
Item Status | A |
Mfr. # | U208C |
Number Of Cutouts | 1 |
Phase | 1 |
Special Features | Heavy galvanized G90 16 GA steel, with highest quality electro-deposition finish, resists corrosion and fading 200 or 125 AMP continuous duty meter socket with meterguides and reinforced jaws for ring and ringless type sockets Utility meter socket compartment barriered from breaker mains for utility power protection Rated NEMA 3R - weather proof equipment All terminals accept copper or aluminum wire for added installation flexibility Doors have padlock provision to prevent unauthorized entry Supplied with 12-2 Cu/Al equipment ground lug All GFCI duplexes are listed as weather resistant and tamper resistant as required by 2008 NEC in article 406.8 and 406.11 Removable post door allows lay in wiring 200 AMP Factory wired loop feed lugs Rolled edge post bottoms to protect service cable Locking hasp for utility seal on post covers One heads Overhead feed CB2200B installed breaker 8 additional breaker spaces per head Series wiring configuration Provide circuit protection Hub provision LC1212PC load center No loop feed |
Standard | UL Listed |
Type | Unmetered Power Outlet |
UNSPSC | 39121102 |
Voltage Rating | 120/240 |