Sign in or register to view your pricing and inventory.

GE Distribution TM30412C PowerMark Gold™ and Plus™ Standard Main Breaker Load Center; 208/120 Volt AC, 125 Amp, 1 Inch: 30, 1/2 Inch: 14 Space, 30 Circuit, 3 Phase

  • GE Distribution TM30412C GE Distribution TM30412C PowerMark Gold™ and Plus™ Standard Main Breaker Load Center; 208/120 Volt AC, 125 Amp, 1 Inch: 30, 1/2 Inch: 14 Space, 30 Circuit, 3 Phase
  • GE Distribution TM30412C PowerMark Gold™ and Plus™ Standard Main Breaker Load Center; 208/120 Volt AC, 125 Amp, 1 Inch: 30, 1/2 Inch: 14 Space, 30 Circuit, 3 Phase
Manufacturer: GE Distribution
Mfr. #: TM30412C
Item #: 1548
UPC: 783164190007
Login for Availability
Your Price:

Product Details

Size: 14 Inch Width x 3.750 Inch Depth x 33-3/16 Inch Height

Suitable for use as service entrance equipment when installed in accordance with the national electrical code

60 deg C/75 deg C conductor rating

Straight through main wiring

Main breaker is clearly marked and circuit numbers are stamped on front

Compact box maintains optimum wire-bending space

Detailed Description: GE Distribution PowerMark Gold™ and Plus™ 3-Phase Main breaker load center has voltage rating of 208 Y/120 VAC and a current rating of 125 Amps. The 4-Wire main breaker loadcenter has 30 spaces of 1 Inch for one pole in Thql, 14 spaces of 1 Inch for two poles in Thql and 8 spaces of 1 Inch for three pole in Thql. It has interrupt capacity rating of 22 kilo-Amps and has Nema 1, indoor enclosure. It accommodates 2/0 -3/0 AWG size of aluminum main wire and 1 - 3/0 AWG size of copper main wire. It measures 14 Inch x 3.750 Inch x 33-3/16 Inch. It has 30 circuits. Loadcenter is UL listed.

Product Specification

Amperage Rating 125 A
Application Electrical distribution and Control
Brand GE
Catalog Description Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 412C0007
Enclosure Indoor
GTIN 00783164190007
Height 33.200000000000000
Height Unit IN
Interrupt Rating 22
Item Status A
Length 35.2500
Length UOM IN
Load Regulation 208Y/120V ac
Mfr. # TM30412C
Number Of Feeders Top
Phase 3 Phase
Special Features "Main breaker load centers arrive with a main breaker installed for a convenient and swift install. Main breakers allow for the user to stop the flow of electricity in the load center, shutting off all the power in the residence. The TM30412C features spaces for 30, 1"" breakers, a 125A main ampere rating, 3 phases, and a combination surface/flush enclosure."
Standard UL
Type Standard
UNSPSC 39121101
Width 33.200000000000000
Width UOM IN
Wiring Configuration 4 Wire