Size: 11.250 Inch Width x 3.250 Inch Depth x 11.125 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
Detailed Description:
GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible main load center has durable copper bus construction. It has voltage rating of 120/240 VAC, current rating of 125 Amps and interrupting capacity of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has THQL/THQP type main breaker for added safety and protection. Load center has 16 circuits, 8 spacing's of 1-Inch and 42/4/24/16 spacing's of 1/2-Inch for convenient operation. Load center has 8 spaces for 1-Pole 1-Inch THQL breakers and 4 spaces for 2-Pole 1- Inch THQL breakers. It has 16 spaces for 1-Pole 1/2-Inch THQP breakers and 6 spaces for 2-Pole 1/2-Inch THQP breakers. It can accommodate aluminum/copper wires of size 6 - 1 AWG.
Residential load center can be used as service entrance equipment, when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. Conductor operates at a temperature of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. It measures 11.250 Inch x 3.250 Inch x 11.125 Inch. Load center has flush/plug-in breaker mounting for easy installation. Load center is UL listed, CSA certified and GSA complaint.
Amperage Rating | 125 A |
Brand | GE |
Catalog Description | Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A FCUD8041 |
Enclosure | Indoor |
GTIN | 00783164268041 |
Height | 4.8750 |
Height Unit | IN |
Interrupt Rating | 65 |
Item Status | A |
Length | 13.0000 |
Length UOM | IN |
Load Regulation | 120/240V ac |
Mfr. # | TLM812FCUD |
Mounting | 0 |
Number Of Feeders | Either |
Phase | 1 Phase |
Special Features | "PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM812FCUD features space for 8, 1"" breakers, 125 A bus ampere rating, a copper bus, an optional door for 6-8 circuit panel, a factory installed ground bar, and a surface enclosure." |
Standard | UL |
Type | Standard |
UNSPSC | 39121101 |
Width | 13.0000 |
Width UOM | IN |
Wiring Configuration | 3 Wire |