GE Distribution TLM2020CCU PowerMark Gold™ Standard Convertible Main Load Center; 200 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 20, 1/2 Inch: 42, 4, 24, 16, 20, 32, 40 Space, 40 Circuit, 3-Wire, Flush/Surface

  • GE Distribution TLM2020CCU GE Distribution TLM2020CCU PowerMark Gold™ Standard Convertible Main Load Center; 200 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 20, 1/2 Inch: 42, 4, 24, 16, 20, 32, 40 Space, 40 Circuit, 3-Wire, Flush/Surface
  • GE Distribution TLM2020CCU PowerMark Gold™ Standard Convertible Main Load Center; 200 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 20, 1/2 Inch: 42, 4, 24, 16, 20, 32, 40 Space, 40 Circuit, 3-Wire, Flush/Surface
Manufacturer: GE Distribution
Mfr. #: TLM2020CCU
Item #: 23779
UPC: 783164112375
Login for Availability
Your Price:

Product Details

Size: 15.360 Inch Width x 3.750 Inch Depth x 27.810 Inch Height

One piece interior removes and reinstalls easily

Full-length neutrals are easier to wire,2 reducing installation time and cost

Minimum 100% neutral terminations

Combination slotted/robertson square-drive speeds screw wiring

All holes rated for 14-4 wire

100% rated split neutral on each side

Tie bar may be removed to split neutral/ground

Detailed Description: GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible main load center has durable copper bus construction. It has voltage rating of 120/240 VAC and current rating of 200 Amps. It has interrupting rating of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has THQL/THQP type main breaker for added safety and protection. Load center has 40 circuits, 20 spacing of 1-Inch and 42/4/24/16/20/32/40 spacing of 1/2-Inch for convenient operation. Load center has 20 spaces for 1-Pole/1-Inch THQL breakers and 10 spaces for 2-Pole/1-Inch THQL breakers. It has 40 spaces for 1-Pole/0.5-Inch THQP breakers and 18 spaces for 2-Pole/0.5-Inch THQP breakers.

Load center operates at a temperature of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. It has flush/surface cover to improve aesthetic look. It can accommodate 6 AWG-250 kcmil aluminum/copper wires It has plug in breaker mounting for easy installation. It measures 15.360 Inch x 3.750 Inch x 27.810 Inch. Load center is UL listed, CSA certified and GSA complaint.

Product Specification

Amperage Rating 200 A
Brand GE
Catalog Description Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 200 A 0CCU2375
Enclosure Indoor
GTIN 00783164112375
Height 26.400000000000000
Height Unit IN
Interrupt Rating 65
Item Status A
Length 28.5000
Length UOM IN
Load Regulation 120/240V ac
Mfr. # TLM2020CCU
Mounting 0
Number Of Feeders Either
Phase 1 Phase
Special Features "PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM2020CCU features space for 20, 1"" breakers, 200 A bus ampere rating, a copper bus, and a combination/flush enclosure."
Standard UL
Type Standard
UNSPSC 39121101
Width 16.0000
Width UOM IN
Wiring Configuration 3 Wire