Sign in or register to view your pricing and inventory.

GE Distribution TLM1612CCU PowerMark Gold™ Standard Convertible Main Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 24 Circuit, 3-Wire, Flush/Surface

  • GE Distribution TLM1612CCU GE Distribution TLM1612CCU PowerMark Gold™ Standard Convertible Main Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 24 Circuit, 3-Wire, Flush/Surface
  • GE Distribution TLM1612CCU PowerMark Gold™ Standard Convertible Main Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 24 Circuit, 3-Wire, Flush/Surface
Manufacturer: GE Distribution
Mfr. #: TLM1612CCU
Item #: 23463
UPC: 783164156737
Login for Availability
Your Price:

Product Details

Size: 15.360 Inch Width x 3.750 Inch Depth x 20.380 Inch Height

One piece interior removes and reinstalls easily

Full-length neutrals are easier to wire,2 reducing installation time and cost

Minimum 100% neutral terminations

Combination slotted/robertson square-drive speeds screw wiring

All holes rated for 14-4 wire

100% rated split neutral on each side

Tie bar may be removed to split neutral/ground

Detailed Description: GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard convertible main load center has durable copper bus construction. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting rating of 65 Kilo-Amps. It has top/bottom feed for convenience. Load center has THHQL/THQL/THQP/TQMH/TXQL type main breaker for added safety and protection. Load center has 24 circuits, 16 spacing of 1-Inch and 42/4/24/16/20/32/40 spacing of 1/2-Inch for convenient operation. Load center has 16 spaces for 1-Pole/1-Inch THQL breakers and eight spaces for 2-Pole/1-Inch THQL breakers. It has 16 spaces for 1-Pole/0.5-Inch THQP breakers and six spaces for 2-Pole/0.5-Inch THQP breakers.

Load center operates at a temperature of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kilo-Amps. It can accommodate aluminum/copper wires of size 6 to 2/0 AWG. It has plug in breaker mounting for easy installation. It measures 15.360 Inch x 3.750 Inch x 20.380 Inch. Load center is UL listed, CSA certified and GSA complaint.

Product Specification

Amperage Rating 125
Brand GE
Catalog Description Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 2CCU6737
Enclosure Indoor
GTIN 00783164156737
Height 5.5000
Height Unit IN
Interrupt Rating 65
Item Status A
Length 21.1250
Length UOM IN
Load Regulation 120/240V ac
Mfr. # TLM1612CCU
Mounting 0
Number Of Feeders Either
Phase 1
Special Features "PowerMark Gold convertible load centers arrive as main lug, but have the capability to have a main breaker installed. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TLM1612CCU features space for 16, 1"" breakers, a 125 A bus ampere rating, a copper bus, and a combination/flush enclosure."
Standard UL
Type Standard
UNSPSC 39121101
Width 16.0000
Width UOM IN
Wiring Configuration 3 Wire