Size: 15.360 Inch Width x 3.750 Inch Depth x 26.060 Inch Height
One piece interior removes and reinstalls easily
Full-length neutrals are easier to wire,2 reducing installation time and cost
Minimum 100% neutral terminations
Combination slotted/robertson square-drive speeds screw wiring
All holes rated for 14-4 wire
100% rated split neutral on each side
Tie bar may be removed to split neutral/ground
Detailed Description:
GE Distribution PowerMark Gold™ 3-Phase 4-Wire Load center has durable copper bus construction. It has voltage rating of 208/120 VAC for star connection and current rating of 150 Amps. It has interrupting capacity rating of 65 Amps. Load center has THQL type main breaker for added safety and protection. Load center has 24 circuits and 24 1-Inch space for convenient operation. It has top/bottom feed for convenience. Load center has 24 spaces for 1-Pole/1-Inch, 12 spaces for 2-Pole/1-Inch and 8 spaces for 3-Pole/1-Inch THQL breakers. It can accommodate aluminum wires of size 2/0 - 3/0 AWG and copper wires of size 1 - 3/0 AWG.
Load center has conductor temperature rating of 60/75 deg C. It measures 15.360 Inch x 3.750 Inch x 26.060 Inch. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. It has surface/flush cover to improve aesthetic look. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kAIC. It measures 15.360-Inch x 3.750 Inch x 26.060-Inch. It can be used in commercial or high-rise residential applications. It has plug-in breaker mounting for easy installation. Load center is UL listed.
Amperage Rating | 150 |
Brand | GE |
Catalog Description | Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 150 A 415C9919 |
Enclosure | Indoor |
GTIN | 00783164189919 |
Height | 24.7 |
Height Unit | IN |
Interrupt Rating | 65 |
Item Status | A |
Length | 26.7500 |
Length UOM | IN |
Load Regulation | 208Y/120V ac |
Mfr. # | TL24415C |
Mounting | 0 |
Number Of Feeders | Either |
Phase | 3 |
Special Features | "Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL24415C features space for 24, 1"" breakers, 40 A bus ampere rating, and a combintation/flush enclosure." |
Standard | UL |
Type | Standard |
UNSPSC | 39121101 |
Width | 24.700000000000000 |
Width UOM | IN |
Wiring Configuration | 4-Wire |