Dimensions: 8.500 Inch Length x 12.200 Inch Width x 3.500 Inch Height
ARCHOS 43 Internet Tablet provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations
Cross-channel and current triggering capture every measurement, on every channel, every time
Easily analyze data and generate reports with automated EN50160 reporting and compliance
Auto Report creates either standard reports or customized reports with the minimum effort or hassle
Set up in minutes with self-identifying current probes and single-lead voltage connections
Swap channels internally with the wireless PDA or PC when connections are not correct
Get a detailed picture of even the shortest events
Detailed Description: Fluke 3-Phase Power recorder features cross-channel and current triggering capture. It measures 8.500 Inch x 12.200 Inch x 3.500 Inch. It helps to analyze data easily and generate reports with automated EN50160 reporting/compliance. Recorder set up in minutes with self-identifying current probes and single-lead voltage connections. It comes with auto report that creates either standard reports or customized reports with the minimum effort/hassle. It has a voltage rating of 1000 VAC RMS and 1000 VDC. Recorder can swap channels internally with the wireless PDA or PC when connections are not correct. It operates at frequency of 42.5 - 69 Hz and temperature of -20 to 50 deg C. Recorder is ideal for long-term analysis, power quality surveys, quality of service compliance and equipment installation/commissioning applications. Recorder meets IE standards.
Dimensions | 8.500 Inch Length x 12.200 Inch Width x 3.500 Inch Height |
Accuracy | +/- 10 Milli-Hz (10 - 110 % of Range, With Sine Wave) For Frequency, +/- 1 Digit From the Calculation of Each Measured Value (+/-3 Digits for Total) For Power Factor |
Alternate Part Number | 2157153 |
Application | For Long-Term Analysis, Power quality surveys, Quality of service compliance, Equipment Installation/Commissioning |
Brand | Fluke |
Catalog Description | Record every power quality paramater, every cycle, all the time. Discover why thousands of worldwide users choose the Fluke 1750 and why there is no other unit on the market like it. Easily record three-phase power quality and monitor for power quality disturbances with the Fluke 1750 Power Recorder and the Fluke Power Analyze software. These power meters automatically record every power quality parameter and event, on every cycle n++ all the time. Common Applications---Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction; Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports; Quality of service compliance: Validate incoming power quality at the service entrance; Equipment Installation/Commissioning: Benchmark power system prior to install to ensure quality of service. |
Country Of Origin | UKN |
Degree Of Protection | IP30 |
Environmental Conditions | Storage: 80% Humidity Maximum Non-Condensing, Operating: 80% Relative Maximum Non-Condensing |
EU RoHS Indicator | U |
Frequency Rating | 42.5 - 69 Hz |
GTIN | 00095969262941 |
Includes | 1750 Acquisition Unit, ARCHOS 43 Internet Tablet, 4 - 400 Amp Current Probes (3140), 5 Test Leads and Clips, SD Memory Card, Fluke Power View and Fluke Power Analyze Software, Power Cord With International Plug Set, Ethernet Cable, Color Localization Set, Printed Getting Started Manual, Product CD With Software and User Manual PDF, CS 1750/1760 Rugged Transit Softcase |
Item | 3-Phase Power Recorder |
Memory | 2 GB Internal Memory |
Mfr. # | FLUKE-1750 |
Model | Fluke 1750/B |
Special Features | Power quality that meets the standard: All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc; Quick and reliable configuration: ARCHOS 43 Internet Tablet provides a window into what the instrument is recording, enabling quick and reliable configuration even in awkward test locations; Threshold-free set up: Apply thresholds after data is collected with Fluke Power Analyze Software û no need to worry about missed information due to incorrect setups; Captures everything: Cross-channel and current triggering capture every measurement, on every channel, every time; Intuitive PC software: Easily analyze data and generate reports with automated EN50160 reporting and compliance; Reporting has never been easier: Auto Report creates either standard reports or customized reports with the minimum effort or hassle; Plug and play: Set up in minutes with self-identifying current probes and single-lead voltage connections; No need to reconnect wires: Swap channels internally with the wireless PDA or PC when connections are not correct; Measure every parameter: Voltage and current on three phases, neutral, and ground; 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events; Quickly retrieve data: With included SD memory card or via the 100BaseT high-speed Ethernet connection. SD card includes automatic download to SD when no other connection is made to the instrument. |
Standard | EMC---EN 61326-1:1997+A1:1998 Class A; EN 61000-3-2:1995+A1:1998+A2:1998; EN 61000-3-3:1995; Safety---EN 61010-1 2nd Edition, 2000; Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) |
Standards | IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160 |
Temperature Rating | -20 to 50 deg C |
Type | Power Quality Logger |
Voltage Rating | 1000 Volt AC RMS, 1000 Volt DC |