Sign in or register to view your pricing and inventory.

Appleton EYDM75 Vertical Drain Seal Fitting with Removable Nipple, 3/4 inch, FNPT x FNPT, Malleable Iron

  • Appleton APPEYDM75 Appleton EYDM75 Vertical Drain Seal Fitting with Removable Nipple, 3/4 inch, FNPT x FNPT, Malleable Iron
Manufacturer: Appleton
Mfr. #: APPEYDM75
Item #: 430923
UPC: 781381230070
Login for Availability
Your Price:

Product Details

Explosion proof, dust-ignition proof and raintight

Smooth, rounded integral bushing

Accurately tapped, tapered threads for tight, rigid joints and ground continuity

UL listed

CSA certified

Detailed Description: Appleton sealing fitting prevent passage of gases, vapours or flames from one portion of conduit system to another. Restrict any explosion to the sealed off enclosure. Prevent pressure piling within conduit system.

Product Specification

Application For Use With Threaded Rigid Metal Conduit and IMC
Brand Appleton
Catalog Description UNILETS EYDM Series 25 PCT Fill Vertical Conduit Drain Sealing Fitting With Removable Nipple, Size: 3/4 IN, Material: Malleable Iron, Finish: Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat), Connection: Tapered MNPT X Taper
Connection Tapered MNPT X Tapered FNPT
Finish Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat)
GTIN 00781381230070
Height 1.0200
Height Unit IN
Item Status A
Length 8.4000
Length UOM IN
Material Malleable Iron
Mfr. # EYDM75
Size 3/4
Special Features For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; U
Standard UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D; Class II, Groups E, F, G; And Class III
Type EYDM Series 25 PCT Fill Vertical Conduit Drain Sealing Fitting With Removable Nipple
UNSPSC 39121311
Width 5.7000
Width UOM IN