Sign in or register to view your pricing and inventory.

ACME T181049 Acme, Buck Boost Transformer, 12/24V 150VA

  • Acme Transformer T181049 ACME T181049 Acme, Buck Boost Transformer, 12/24V 150VA
Manufacturer: Acme Transformer
Mfr. #: T181049
Item #: 129548
UPC: 047503089651
Login for Availability
Your Price:

Product Details

Detailed Description: T181049 ACME .150KVA BUCK&BOOST

Product Specification

Application For Low Voltage Lighting Or Control Circuitry
Boost Voltage 1.51 KVA/6.25 AMP: 220 V Line And 242 V Load
Brand Acme Electric
Buck Voltage 3 KVA/13.1 AMP: 252 V Line And 240 V Load
Catalog Description Acme Electric T-1-81049 Transformer, Encapsulated Core And Coil Buck-Boost, 120/240 V, 12/24 V, 3 KVA/13.1 AMP: 252 V Line And 240 V Load Buck Voltage, 1.51 KVA/6.25 AMP: 220 V Line And 242 V Load Boost Voltage, 60 HZ, 1 PH, 12.52 AMP At 12 V, 6.25 AMP At 24 V, 115 DEG C Rise, Wire Lead Screw Terminal Connection, 130 DEG C Class B Insulation, Wall Mounting, NEMA 3R, 3.89 IN Length, 3.67 IN Width, 7.16 IN Height, 0.15 KVA, Steel, Configuration: Primary: Two Winding, Secondary: Two Winding, UL 506, UL File Number E79947V1, UL Control Number 50B8, UL Insulation Number B3223, CSA Certified, OSHA Compliant, ANSI, IEEE, For Low Voltage Lighting Or Control Circuitry
Connection Wire Lead Screw Terminal
Enclosure NEMA 3R Steel
Frequency Rating 50/60
GTIN 00047503089651
Height 7.16
Height Unit IN
Insulation Class 130 DEG C Class B
Item Status A
Length 3.67
Length UOM IN
Maximum Output Current 12.52 AMP At 12 V, 6.25 AMP At 24 V
Mfr. # T181049
Mounting Wall
Number Of Phases 1
Primary Voltage 120 X 240 V
Replaced UPC 047503183380
Secondary Voltage 12/24 V
Special Features Encapsulated core and coil; Buck-boost transformers are small single phase transformers designed to reduce (buck) or raise (boost) line voltage from 5 - 20 PCT; The most common example is boosting 208 - 230 V, usually to operate a 230 V motor such as an air-conditioner compressor, from a 208 V supply line; Buck-boost transformers are an economical way to correct a potentially very serious problem; Anytime a line voltage change in the 5 - 20 PCT range is required, a buck-boost transformer should be considered as your first line of defense; 10-year limited warranty
Standard UL 506, UL File Number E79947V1, UL Control Number 50B8, UL Insulation Number B3223, CSA Certified, OSHA Compliant, ANSI, IEEE
Temperature Rating 115 DEG C Rise
Type Buck-Boost Transformer
UNSPSC 39121025
Width 3.89
Width UOM IN